The Cisco Nexus® 3048 Switch (Figure 1 – N3K-C3048TP-1GE) is a line-rate Gigabit Ethernet Top-of-Rack (ToR) switch and is part of the Cisco Nexus 3000 Series Switches portfolio. The Cisco Nexus 3048, with its compact one-Rack-Unit (1RU) form factor and integrated Layer 2 and 3 switching, complements the existing Cisco Nexus family of switches. This switch runs the industry-leading Cisco®NX‑OS Software operating system, providing customers with robust features and functions that are deployed in thousands of data centers worldwide. The Cisco Nexus 3048 is ideal for big data customers that require a Gigabit Ethernet ToR switch with local switching that connects transparently to upstream Cisco Nexus switches, providing an end-to-end Cisco Nexus fabric in their data centers. This switch supports both forward and reversed airflow schemes with AC and DC power inputs.
- 48 fixed 10/100/1000-Mbps Ethernet ports
- 4 fixed Enhanced Small Form-Factor Pluggable (SFP+) ports
- Locator LED
- Dual redundant power supplies
- Fan tray with redundant fans
- Two 10/100/1000-Mbps management ports*
- One RS-232 serial console port
- One USB port
- Locator LED and button
CISCO NEXUS 3048 SWITCH (N3K-C3048TP-1GE) SPECIFICATION
Description |
Specification |
Physical |
● 1RU fixed form-factor switch
● 48 10/100/1000-Mbps RJ-45 ports
● 4 1/10 Gbps SFP+ uplink ports
● 2 redundant power supplies
● 1 fan tray with redundant fans
● 1 I/O module with management, console, and USB flash memory ports
|
Performance |
● 176-Gbps switching capacity
● Forwarding rate of 132 mpps
● Line-rate traffic throughput (both Layer 2 and 3) on all ports
● Configurable Maximum Transmission Units (MTUs) of up to 9216 bytes (jumbo frames)
|
Hardware tables and scalability |
MAC addresses |
128,000 |
Number of VLANS |
4096 |
Spanning-tree instances |
● RSTP: 512
● MSTP: 64
|
ACL entries |
2000 ingress
1000 egress |
Routing table |
16,000 prefixes and 16,000 host entries*
8000 multicast routes* |
Number of EtherChannels |
52 (with vPC) |
Number of ports per EtherChannel |
16 |
Buffers |
9 MB shared |
Boot flash memory |
2 GB |
Power |
Number of power supplies |
2 (redundant) |
|
Typical operating power |
120 watts (W) (48p of 1G and 4p of 10G/SR at 100% load, with 2 Power Supply Units [PSUs]) |
|
Maximum power |
124W |
|
AC PSUs
● Input voltage
● Frequency
● Efficiency
|
100 to 240 VAC
50 to 60 Hz
89 to 91% at 220V |
|
DC PSUs
● Input voltage
● Maximum current
● Efficiency
|
-40 to -72 VDC
33A
85 to 88% |
|
Typical heat dissipation |
409 BTU/hr (48p of 1G and 4p of 10G/SR at 100% load, with 2 PSUs) |
|
Maximum heat dissipation |
423 BTU/hr |
Cooling |
Forward and reversed airflow schemes
Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)
Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)
Single fan tray with redundant fans
Hot swappable (must swap within 1 minute) |
Sound |
Measured sound power (maximum)
● Fan speed: 40% duty cycle
● Fan speed: 60% duty cycle
● Fan speed: 100% duty cycle
|
63.9 dBA
64.7 dBA
66.4 dBA |
Environment |
Dimensions (height x width x depth) |
1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
Weight |
20.5 lb (9.3 kg) |
Operating temperature |
32 to 104°F (0 to 40°C) |
Storage temperature |
-40 to 158°F (-40 to 70°C) |
Operating relative humidity |
10 to 85% noncondensing
Up to 5 days at maximum (85%) humidity
Recommend ASHRAE data center environment |
Storage relative humidity |
5 to 95% noncondensing |
Altitude |
0 to 10,000 ft (0 to 3000m) |